Motor-Evoked Potential Monitoring With Multi-train Electrical Stimulation During Thoracoabdominal Aortic Aneurysm Surgery: A Case Report

胸腹主动脉瘤手术中应用多脉冲电刺激进行运动诱发电位监测:病例报告

阅读:1

Abstract

Intraoperative motor-evoked potentials (MEPs) are measured for assessing motor function during surgery. MEP monitoring is often performed in thoracoabdominal aortic aneurysm (TAAA) surgery, but false positives are common and amplification methods are needed to obtain waveforms under severe conditions to assess proper spinal cord function. One method of amplitude amplification in transcranial-stimulated MEP monitoring is multitrain stimulation. There are few reports on multitrain-stimulated MEP monitoring for this surgery. A 57-year-old woman underwent open repair of the thoracoabdominal aorta due to a dissecting aortic aneurysm. After opening the chest, the aneurysm was incised proximally, and anastomosis with an artificial vessel was initiated. The lumbar artery leading to the Adam-Kiewicz artery was reconstructed at a body temperature of 25 °C. However, the single-train stimulation did not produce MEPs. When the measurement was switched to multitrain stimulation, MEPs were elicited in the lower extremity muscle groups and the waveforms were maintained until the end of the measurement. This case illustrates that MEP monitoring using multitrain stimulation during descending thoracic aortic aneurysm surgery can effectively elicit MEPs under challenging conditions, in which conventional single-train stimulation may be insufficient.