One-Year Evaluation of High-Power Rapid Curing on Dentin Bond Strength

高功率快速固化对牙本质粘接强度的一年期评估

阅读:1

Abstract

This study investigated the effect of 3 s light-curing with a high-power LED curing unit on the shear bond strength of bulk-fill composites. Four bulk-fill composites were bonded to dentin with a universal adhesive (Scotchbond Universal Plus): two materials designed for rapid curing (Tetric PowerFill and Tetric PowerFlow) and two controls (Filtek One Bulk Fill Restorative and SDR Plus Bulk Fill Flowable). The 4 mm composite layer was light-cured with Bluephase PowerCure for 20 s at 1000 mW/cm(2) ("20 s") or for 3 s at 3000 mW/cm(2) ("3 s"). The samples were stored at 37 °C in distilled water and tested after 1, 6 and 12 months. The samples polymerised in the "3 s" mode had statistically similar or higher bond strength than the samples cured in "20 s" mode, except for the Tetric PowerFlow (1 month) and SDR+ (6 month). The flowable materials Tetric PowerFlow and SDR Plus initially showed the highest values in the "3 s" and "20 s" groups, which decreased after 12 months. The bond strength was statistically similar for all materials and curing protocols after 12 months, except for Tetric PowerFill cured with the "3 s" protocol (21.22 ± 5.0 MPa), which showed the highest value. Tetric PowerFill showed the highest long-term bond strength. While "3 s" curing resulted in equal or better shear bond strength, its use can only be recommended for a material with an AFCT agent such as Tetric PowerFill.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。