Ocular and the whole body radiation exposure during endoscopic retrograde cholangiopancreatography

内镜逆行胰胆管造影术中眼部和全身辐射暴露

阅读:1

Abstract

OBJECTIVES: This study aimed to analyze the average whole body radiation exposure, which changes significantly according to during endoscopic retrograde cholangiopancreatography (ERCP) difficulty and to determine whether an ocular protection device must be used by analyzing applied ocular radiation. MATERIAL AND METHODS: Patients >18 years of age in whom an ERCP had been indicated were prospectively included in the study. RESULTS: A total of 1173 patients were included. Increased applied radiation dose significantly correlated with increased shot rate (Rho= 0.789, p <0.001), ERCP duration (Rho= 0.487, p <0.001), cost (Rho= 0.129, p <0.001), and LOS (Rho= 0.109, p <0.001). The whole body, skin, and eye radiation exposure doses were found to be lower than the recommended limit per year (20 mSv/year). CONCLUSION: Limit of ocular radiation exposure during ERCP did not exceed the recommended annual limit (20 mSv/year), and it was also detected to be much lower than that. Therefore, the use of ocular visors is not recommended.