[Long-term computed tomographic osteolytic analysis of highly cross-linked polyethylene prosthesis after total hip arthroplasty]

[全髋关节置换术后高交联聚乙烯假体的长期计算机断层扫描骨溶解分析]

阅读:1

Abstract

OBJECTIVE: To analyze the occurrence of osteolysis in total hip arthroplasty (THA) with highly cross-linked polyethylene prosthesis during a follow-up of more than 15 years. METHODS: The clinical data of 84 patients (105 hips) treated with THA in the Affiliated Hospital of Kanazawa Medical University in Japan between June 2000 and April 2004 and met the selection criteria was retrospectively analyzed. There were 7 males and 77 females, aged from 41 to 75 years, with an average of 56.4 years. There were 94 hips with secondary hip osteoarthritis, 4 hips after pelvic osteotomy, 2 hips with primary hip osteoarthritis, 2 hips with traumatic hip osteoarthritis, 2 hips with osteonecrosis of the femoral head, and 1 hip with rheumatoid arthritis. According to Crowe classification, there were 79 hips of type Ⅰ, 19 hips of type Ⅱ, 6 hips of type Ⅲ, and 1 hip of type Ⅳ. The highly cross-linked polyethylene acetabular liner combined with a 26 mm zirconia femoral head were used in all patients. X-ray films were taken after operation to analyze the radiation transmission and osteolysis around the acetabular prosthesis. The vertical distance (the distance between the teardrop line at the lower edge of the pelvis and the perpendicular line of the hip rotation center), the horizontal distance (the horizontal distance between the hip rotation center and the interteardrop line and the vertical line at the lower edge of the teardrop), and the acetabular cup anteversion angle were measured at last follow-up. The acetabular and femoral osteolysis was analyzed by CT scan and three-dimensional multiplanar reconstruction (3D-MPR). Combined with X-ray film and CT results, osteolysis was evaluated according to the Narkbunnam score. RESULTS: Deep vein thrombosis of lower limbs occurred in 2 cases. All patients were followed up 15-18 years, with an average of 15.9 years. One hip dislocation and 1 periprosthetic fracture occurred postoperatively, and no acetabular loosening or prosthetic lining ruptures occurred. Except for 1 patient who had a radiolucent line in the acetabulum after operation, the other 83 patients did not show any radiolucent line in the acetabulum or the femur. None of the patients underwent hip revision. X-ray films at last follow-up showed an acetabular cup anteversion angle of -10°-39°, with an average of 22°; a vertical distance of 3.5-47.1 mm, with an average of 24.6 mm; and a horizontal distance of 22.6-48.1 mm, with an average of 31.7 mm. There was no acetabular or femoral osteolysis in all patients on X-ray films and CT 3D-MPR images at last follow-up, and the Narkbunnam score was 0 in any region. CONCLUSION: Highly cross-linked polyethylene prosthesis does not increase the risk of long-term complications such as osteolysis after THA.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。