Comparison of 5-year cup and stem migration between ceramic-on-ceramic and ceramic-on-polyethylene bearing in press-fit total hip arthroplasty: a randomised controlled trial using radiostereometric analysis

比较陶瓷对陶瓷和陶瓷对聚乙烯轴承在压配式全髋关节置换术中5年髋臼和股骨柄移位情况:一项采用放射立体分析的随机对照试验

阅读:1

Abstract

INTRODUCTION: The inelasticity of ceramic bearings might affect primary stability and migration of implants in press-fit total hip arthroplasty (THA). This randomised controlled trial compares migration patterns of the uncemented Delta-TT cup and H-MAX S stem between ceramic and polyethylene liners, up to 5 years follow-up. METHODS: Patients receiving primary press-fit THA were randomly allocated to a ceramic (n = 28) or polyethylene (n = 25) liner. Migration was measured using model-based radiostereometric analysis (RSA) at baseline and 1.5, 3, 6, 12, 24 and 60 months postoperatively and compared between groups using mixed models statistical analysis. The focus of this study is on the 2- to 5-year migration of the Delta-TT cup and migration during complete follow-up of the H-MAX S stem up to 5-years. RESULTS: At 5-year follow-up, mean (95% CI) proximal cup translation was 0.56 (0.37-0.74) mm in ceramic and 0.58 (0.25-0.90) mm in polyethylene (p = 0.729). The mean change in adduction was 1.05° (0.27-1.82°) in ceramic and 0.78° (-0.16-1.71°) in polyethylene. Mixed modelling showed that all between-group effects were ⩽0.20 mm for translation and ⩽0.22° for rotation at 5 years postoperatively (p ⩾ 0.23). Mean cup migration between 2 and 5 years was limited (all parameters <0.17 mm and <0.30°). At 5-year follow-up, mean stem subsidence was 2.09 mm (0.89-3.29 mm) in ceramic and 2.55 (0.97-4.12) mm in polyethylene. The mean change in internal rotation was 3.69° (1.98-5.40°) in ceramic and 4.01° (2.20-5.81°) in polyethylene. Most stem migration occurred up to 1.5 months, stabilising afterwards. All between-group effects were ⩽0.75 mm for translations and ⩽1.41° for rotations (p ⩾ 0.26). CONCLUSIONS: 5-year migration patterns of press-fit cups and stems were similar between ceramic and polyethylene liners. The Delta-TT cup and H-MAX S stem showed secondary stabilisation and remained stable up to 5 years in both groups, which is promising for long-term survival with both liner types. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov (NCT03093038).

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。