The MyJump App is a Valid Method of Assessing and Classifying Limb Symmetry During Recovery from Anterior Cruciate Ligament Reconstruction

MyJump应用程序是一种评估和分类前交叉韧带重建术后恢复期间肢体对称性的有效方法。

阅读:1

Abstract

BACKGROUND: Jump testing performance and limb symmetry measures are important metrics for clinicians to monitor during rehabilitation after Anterior Cruciate Ligament (ACL) reconstruction, however they require hardware and software which is not commonly available in clinical practice. Video-based solutions may present a feasible alternative, but their veracity in classifying patients using limb-symmetry of 90% has not been established, nor have the clinimetric values for the performance measures been reported in this population. PURPOSE: To describe the diagnostic accuracy (pass/fail using 90% LSI) and clinimetrics of an iPad-based app ("MyJump") compared to reference force plate analyses for limb symmetry, jump/hop height, contact time, flight time, and reactive strength index. STUDY DESIGN: Prospective cohort, diagnostic accuracy. METHODS: Fifty-one consecutive patients recovering from ACL reconstruction undertaking routine independent clinical evaluation of their hop and jump performance were concurrently and independently examined using force plates and the MyJump app. Diagnostic accuracy of MyJump was compared to reference force plate analyses using a criterion of 90% limb symmetry. RESULTS: Diagnostic accuracy of the MyJump app was very good: positive predictive value for jump height was 0.83 and 1.0 for reactive strength index, and negative predictive value was 0.95 and 1.0 for the same metrics, respectively. Of the 131 classifications made using the MyJump app, there were five false positives and three false negatives - all of these were in classification of jump height with no misclassifications of RSI. Irrespective of jump type, the MyJump app displayed excellent reliability (ICC>0.95) for both height and reactive strength index. Minimum detectable changes were approximately 1cm for height, 0.1 for reactive strength index, 0.02s for contact time, and 0.3s for flight time. CONCLUSION: Where force plates are unavailable, the MyJump app is a valid and reliable substitute for criteria assessment of jump/hop height and reactive strength index in those recovering from ACL surgery using a 90% limb symmetry threshold. The minimum detectable changes vary by metric but are likely sufficiently accurate to detect clinical changes. LEVEL OF EVIDENCE: Level 3.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。