Multimodal Remote Home Monitoring of Lung Transplant Recipients during COVID-19 Vaccinations: Usability Pilot Study of the COVIDA Desk Incorporating Wearable Devices

新冠疫苗接种期间肺移植受者多模式远程居家监测:COVIDA Desk 整合可穿戴设备的可用性试点研究

阅读:1

Abstract

Background and Objectives: Remote patient monitoring (RPM) of vital signs and symptoms for lung transplant recipients (LTRs) has become increasingly relevant in many situations. Nevertheless, RPM research integrating multisensory home monitoring in LTRs is scarce. We developed a novel multisensory home monitoring device and tested it in the context of COVID-19 vaccinations. We hypothesize that multisensory RPM and smartphone-based questionnaire feedback on signs and symptoms will be well accepted among LTRs. To assess the usability and acceptability of a remote monitoring system consisting of wearable devices, including home spirometry and a smartphone-based questionnaire application for symptom and vital sign monitoring using wearable devices, during the first and second SARS-CoV-2 vaccination. Materials and Methods: Observational usability pilot study for six weeks of home monitoring with the COVIDA Desk for LTRs. During the first week after the vaccination, intensive monitoring was performed by recording data on physical activity, spirometry, temperature, pulse oximetry and self-reported symptoms, signs and additional measurements. During the subsequent days, the number of monitoring assessments was reduced. LTRs reported on their perceptions of the usability of the monitoring device through a purpose-designed questionnaire. Results: Ten LTRs planning to receive the first COVID-19 vaccinations were recruited. For the intensive monitoring study phase, LTRs recorded symptoms, signs and additional measurements. The most frequent adverse events reported were local pain, fatigue, sleep disturbance and headache. The duration of these symptoms was 5-8 days post-vaccination. Adherence to the main monitoring devices was high. LTRs rated usability as high. The majority were willing to continue monitoring. Conclusions: The COVIDA Desk showed favorable technical performance and was well accepted by the LTRs during the vaccination phase of the pandemic. The feasibility of the RPM system deployment was proven by the rapid recruitment uptake, technical performance (i.e., low number of errors), favorable user experience questionnaires and detailed individual user feedback.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。