Clinical Application of Proximal Arch Cannulation in the Surgical Treatment of Acute Type I Aortic Dissection

近端弓部插管在急性I型主动脉夹层外科治疗中的临床应用

阅读:1

Abstract

Objective The goal is to determine the best location for inserting a catheter into the aortic arch of patients with a certain type of aortic dissection (DeBakey type I) by analyzing images of the patient's aortic arch before surgery. This analysis will take into account the shape and structure of the patient's aortic arch to find the most optimal location for cannulation. Methods A retrospective analysis was conducted on 100 patients with acute DeBakey type I aortic dissection diagnosed between January 2021 and February 2023, utilizing the Carestream medical imaging software Image Suite V4 (New York, USA). The study included 67 cases that underwent surgery and 33 cases that did not. The study aimed to evaluate the optimal intubation position on the patient's aortic arch by analyzing the true and false lumen classification, true and false lumen area, and hematoma thickness on the patient's aortic arch, as observed in the aortic computed tomography angiography (CTA) conducted upon admission. Results The vascular axis analysis showed a significant difference in the true lumen area among the three regions that were examined (P < 0.001). Zone 1 had a larger true lumen area of 6.40 ± 2.71 cm(2) compared to zone 2 with 5.75 ± 2.13 cm(2) and zone 3 with 4.85 ± 1.70 cm(2), as determined by statistical analysis. In addition, the statistical analysis of hematoma thickness in the three regions where cannulation can be performed revealed a significant difference among the three groups (P = 0.027). Further analysis showed that there was no significant difference between zone 1 and zone 2 (P = 1.000), a significant difference between zone 1 and zone 3 (P < 0.046), and no significant difference between zone 2 and zone 3 (P = 0.080). The difference between zone 1 false lumen thickness of 1.55 ± 0.51 cm and zone 3 false lumen thickness of 1.33 ± 0.55 cm was found to be small. Conclusion Cannulation of the aortic arch is a common strategy used in cardiac surgery. Accurate cannulation is critical to the success of the procedure. The use of CTA provides valuable guidance for the cannulation procedure. A thorough examination of CTA and precise measurement of relevant parameters can help guide the surgeon to determine the optimal cannulation site. The study found that zone 1 of the aortic arch has the largest area and is the most suitable for cannulation, in accordance with the physiological characteristics and surgical practices of a surgeon. Furthermore, cannulation of the aortic arch has been found to be a safe and effective strategy for cannulation. Overall, careful examination of CTA and accurate measurement of relevant parameters can have a significant guiding effect on the cannulation of the aortic arch, which can lead to improved outcomes in cardiac surgery.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。