Impact of coronary bifurcation angle on stent malapposition in a randomized comparison between proximal optimization technique followed by side branch dilatation and kissing balloon inflation

冠状动脉分叉角度对支架贴壁不良的影响:一项随机对照研究比较了近端优化技术联合侧支扩张和双球囊扩张两种方法。

阅读:1

Abstract

BACKGROUND: The impact of coronary bifurcation angle (BA) on incomplete stent apposition (ISA) after crossover stenting followed by side branch (SB) intervention has not been established. METHODS: A total of 100 crossover stentings randomly treated with proximal optimization technique followed by short balloon dilation in the SB (POT-SBD group, 48 patients) and final kissing balloon technique (KBT group, 52 patients) were analyzed in the PROPOT trial. Major ISA with maximum distance > 400 μm and its location was determined using optical coherence tomography before SB intervention and at the final procedure. The BA was defined as the angle between the distal main vessel and SB. Optimal POT was determined when the difference in stent volume index between the proximal and distal bifurcation was greater than the median value (0.86 mm(3)/mm) before SB intervention. RESULT: Major ISA was more frequently observed in the POT-SBD than in the KBT group (35% versus 17%, p < 0.05). In the POT-SBD group, worsening ISA after SBD was prominent at the distal bifurcation. The BA was an independent predictor of major ISA (odds ratio 1.04, 95% confidence interval 1.00-1.07, p < 0.05) with a cut-off value of 59.5° (p < 0.05). However, the cases treated with optimal POT in the short BA (<60°) indicated the lowest incidence of major ISA. In the KBT group, BA had no significant impact. CONCLUSION: A wide BA has a potential risk for the occurrence of major ISA after POT followed by SBD in coronary bifurcation stenting.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。