Feasibility of Speech Testing Using Wireless Connection in Single-Sided Cochlear Implant Users

单侧人工耳蜗植入者使用无线连接进行语音测试的可行性研究

阅读:1

Abstract

BACKGROUND AND OBJECTIVES: The speech tests used to evaluate language performance in patients with bilateral deafness (BiD) and cochlear implant (CI) are problematic if applied to patients with single-sided deafness (SSD) because normal ear hearing should be excluded. Thus, we investigated the feasibility of using wireless connection to evaluate speech intelligibility of the CI ear in patients with SSD. Subjects and. METHODS: Patients with BiD and SSD were administered the word recognition scores (WRS) and speech intelligibility tests using an iPadbased wireless connection and conventional methods. To exclude normal side hearing in patients with SSD, masking noise and "plugged and muffed" method were used in the WRS and speech intelligibility tests, respectively. RESULTS: In patients with BiD, the WRS and speech intelligibility tests results using wireless connection and conventional methods were similar. In patients with SSD, the WRS using masking noise in the normal hearing ear was similar to that of using wireless connection. However, 3 of 11 patients with SSD showed under-masked results if using the "plugged and muffed" method. CONCLUSIONS: Speech intelligibility testing using wireless connection is a convenient and reliable method for evaluating CI performance in patients with SSD. The "plugged and muffed" method is not recommended for evaluating CI performance in patients with SSD.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。