Detection of low-density Plasmodium falciparum infections using amplicon deep sequencing

使用扩增子深度测序检测低密度恶性疟原虫感染

阅读:15
作者:Angela M Early, Rachel F Daniels, Timothy M Farrell, Jonna Grimsby, Sarah K Volkman, Dyann F Wirth, Bronwyn L MacInnis, Daniel E Neafsey

Background

Deep sequencing of targeted genomic regions is becoming a common tool for understanding the dynamics and complexity of Plasmodium infections, but its lower limit of detection is currently unknown. Here, a new amplicon analysis tool, the Parallel Amplicon Sequencing Error Correction (PASEC) pipeline, is used to evaluate the performance of amplicon sequencing on low-density Plasmodium DNA samples. Illumina-based sequencing of two Plasmodium falciparum genomic regions (CSP and SERA2) was performed on two types of samples: in vitro DNA mixtures mimicking low-density infections (1-200 genomes/μl) and extracted blood spots from a combination of symptomatic and asymptomatic individuals (44-653,080 parasites/μl). Three additional analysis tools-DADA2, HaplotypR, and SeekDeep-were applied to both datasets and the precision and sensitivity of each tool were evaluated.

Conclusions

Amplicon deep sequencing can be used to determine the complexity and diversity of low-density Plasmodium infections. Despite differences in their approach, four state-of-the-art tools resolved known haplotype mixtures with similar sensitivity and precision. Researchers can therefore choose from multiple robust approaches for analysing amplicon data, however, error filtration approaches should not be uniformly applied across samples of varying parasitaemia. Samples with very low parasitaemia and very low read count have higher false positive rates and call for read count thresholds that are higher than current default recommendations.

Results

Amplicon sequencing can contend with low-density samples, showing reasonable detection accuracy down to a concentration of 5 Plasmodium genomes/μl. Due to increased stochasticity and background noise, however, all four tools showed reduced sensitivity and precision on samples with very low parasitaemia (< 5 copies/μl) or low read count (< 100 reads per amplicon). PASEC could distinguish major from minor haplotypes with an accuracy of 90% in samples with at least 30 Plasmodium genomes/μl, but only 61% at low Plasmodium concentrations (< 5 genomes/μl) and 46% at very low read counts (< 25 reads per amplicon). The four tools were additionally used on a panel of extracted parasite-positive blood spots from natural malaria infections. While all four identified concordant patterns of complexity of infection (COI) across four sub-Saharan African countries, COI values obtained for individual samples differed in some cases. Conclusions: Amplicon deep sequencing can be used to determine the complexity and diversity of low-density Plasmodium infections. Despite differences in their approach, four state-of-the-art tools resolved known haplotype mixtures with similar sensitivity and precision. Researchers can therefore choose from multiple robust approaches for analysing amplicon data, however, error filtration approaches should not be uniformly applied across samples of varying parasitaemia. Samples with very low parasitaemia and very low read count have higher false positive rates and call for read count thresholds that are higher than current default recommendations.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。