Evaluating the Efficacy of Volume Isotropic Turbo Spin Echo Acquisition Versus T2-Weighted Turbo Spin Echo Imaging in the Diagnosis of Nerve Root and Perineuronal Pathologies in Spinal Disorders

评估容积各向同性快速自旋回波采集与T2加权快速自旋回波成像在脊柱疾病神经根和神经周围病变诊断中的疗效

阅读:1

Abstract

Background While two-dimensional (2D) turbo spin echo (TSE) sequences offer better through-plane resolution than three-dimensional (3D) isotropic TSE sequences images, with a narrower thickness of the slice, 3D isotropic TSE sequences are known to have a weaker in-plane resolution as well as blurring of the image. These elements may make it more difficult to distinguish between nearby structures that may affect nerve roots and small nerve roots during spinal imaging. This study aimed to analyze the accuracy of T2 TSE sequence and volumetric isotropic TSE acquisition in determining the indentation of nerve roots and perineural diseases such as nerve sheath tumors and Tarlov cysts. Methods Fifty patients who attended the Department of Radiodiagnosis for magnetic resonance (MR) spine participated in this prospective study. Routine MR lumbosacral (LS) spine sequences, such as survey, coronal T2 short-tau inversion recovery (STIR), sagittal T2 TSE, sagittal T1 TSE, and axial T2 TSE, were carried out after a localizer was acquired. More sequences from volume isotropic turbo spin echo acquisition (VISTA) were acquired. For both 2D and 3D sequences, the visibility ratings for perineural cysts, spinal canal stenosis, and nerve root indentation were evaluated. Visibility ratings ranged from zero to four. Results In the cases of perineural cyst, spinal canal stenosis, and nerve root impingement, the mean difference between the VISTA and T2 TSE visibility scores was 0.04, 0.54, and 0.56, respectively. The VISTA and T2 TS had standard deviation differences of 0.006, 0.026, and 0.06, respectively. The "t" values for nerve root impingement, spinal canal stenosis, and perineural cysts were, in order, 50, 180, and 70. Because the p-value was <0.01, a statistically significant variation has been observed. Conclusion In the diagnosis of neural and perineuronal disorders, the visibility scores for 3D T2 TSE (VISTA) were considerably better than those for 2D T2 TSE in identifying perineural cysts, spinal canal stenosis, and nerve root indentation.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。