Excessive orthodontic force can induce inflammatory tooth root resorption due to sustained high stresses within the periodontal ligament (PDL). This study aimed to analyze the PDL pressures during upper incisor retraction using the en masse method with TISAD. The finite element method (FEM) ensured consistent conditions across cases. The models included bone geometry, adjacent teeth, PDL, and orthodontic hardware, analyzed with LS-Dyna. The pressure ranged from 0.37 to 2.5 kPa across the dental arch, with the central incisors bearing 55% of the load. The pressure distribution remained consistent regardless of the force or hook height. The critical pressure (4.7 kPa) was exceeded at 600-650 g force, with notable pressure (3.88 kPa) on the palatal root wall of the right central incisor. Utilizing 0.017 × 0.025 SS archwires in MBT 0.018 brackets provided good torque control and reduced the root resorption risk when forces of 180-200 g per side were applied, maintaining light to moderate stress. Triple forces may initiate resorption, highlighting the importance of nonlinear finite element analysis (FEA) for accurate oral cavity simulations.