An evaluation of properly operated NSF/ANSI-53 Pb certified drinking water filters in Benton Harbor, MI

对密歇根州本顿港市正确运行的 NSF/ANSI-53 Pb 认证饮用水过滤器的评估

阅读:1

Abstract

Communities across the United States and particularly in the Midwest continue to grapple with the complications associated with aging infrastructure. This includes the presence of lead (Pb)-bearing plumbing components such as lead service lines, downstream galvanized iron pipes, and Pb/tin solder. The community of Benton Harbor, MI, experienced six Pb action level exceedances between 2018 and 2021, leading to increasing community concern and a request from the state of Michigan for the US Environmental Protection Agency involvement. Between 9 November and 17 December 2021, US EPA Region 5 and Office of Research and Development, along with the state of Michigan, conducted a water filter efficacy and Pb-nanoparticulate (<100 nm) study to evaluate the performance of NSF/ANSI-53 Pb-certified drinking water filters and the presence of nanoparticulate. In this study, a total of 199 properly installed and operated drinking water filters (combination of faucet mounted and pitcher) were tested in their residential locations. One hundred percent of the water filters were found to perform to the standard to which they were certified, with filtered drinking water Pb concentrations below 5 ppb (maximum observed was 2.5 ppb). In addition, Pb particulate was identified; however, discrete Pb-containing nanoparticles were not widely found or identified.