Numerical study and orthogonal analysis of optimal performance parameters for vertical cooling of sintered ore

烧结矿垂直冷却最佳性能参数的数值研究和正交分析

阅读:1

Abstract

The sinter cooler, essential for cooling hot sintered ore to a specific temperature, has seen recent advancements with the introduction of a vertical sinter cooling furnace. This innovation aims to enhance energy efficiency, reduce emissions, and improve waste heat recovery. Despite significant research, a quantitative analysis of factors impacting its cooling and heat transfer efficiency is lacking. This study utilizes the Euler model and local non-equilibrium thermodynamic theory to identify key factors affecting the gas-solid cooperative cooling process in the vertical cooler. Through an orthogonal experimental approach, the paper determines the optimal structural and operational parameters for the furnace. Key findings include that a gas-solid ratio of 1200m^3/t, inlet air temperature of 50 ℃, cooling section height of 6m, and diameter of 13.25m maximize efficiency, achieving a weighted range normalization value of 0.962. This configuration meets sintered ore cooling requirements while optimizing waste heat recovery. The study reveals that the impact on heat transfer efficiency is influenced primarily by the gas-solid ratio, followed by the cooling section's height, diameter, and inlet air temperature. These insights are crucial for enhancing the vertical sinter cooler's design, contributing to more energy-efficient and environmentally friendly sintering processes.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。