Assessing Neonatal Apgar Scores Following Propofol and Thiopental Induction in Cesarean Sections: A Systematic Review

剖宫产术中丙泊酚和硫喷妥钠诱导后新生儿Apgar评分的评估:系统评价

阅读:1

Abstract

Propofol and thiopental are commonly used induction agents for general anesthesia in cesarean sections. While both are effective, their impact on neonatal outcomes, particularly Apgar scores, remains a subject of clinical interest. Neonatal Apgar scores are critical indicators of early adaptation and are used to assess the immediate well-being of the newborn after delivery. This meta-analysis aimed to compare the effects of propofol and thiopental on neonatal Apgar scores at five minutes following cesarean delivery under general anesthesia. A systematic literature search was performed in PubMed, Embase, Cochrane CENTRAL, and Web of Science for studies published up to 2025. The review followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Inclusion criteria were randomized controlled trials or comparative studies that evaluated pregnant women undergoing cesarean section under general anesthesia, comparing propofol versus thiopental for induction, and reporting neonatal Apgar scores at five minutes. Exclusion criteria included studies with incomplete data, non-comparative designs, or lacking Apgar score reporting. Data were extracted and analyzed using a random-effects model. The primary outcome was the incidence of low Apgar scores (< 7) at five minutes. Pooled odds ratios (ORs) with 95% confidence intervals (CIs) were calculated. Heterogeneity was assessed using I², τ², and χ² statistics. Five studies comprising 657 participants (propofol: n = 506; thiopental: n = 494) met the inclusion criteria. The pooled OR for low Apgar scores at five minutes was 0.93 (95%CI: 0.58-1.49; p = 0.76), indicating no statistically significant difference between the two agents. Heterogeneity was low to moderate (τ² = 0.05; χ² = 5.42; df = 4; p = 0.25; I² = 26%). All included studies were at low risk of bias. These findings suggest that both agents are comparably safe for neonatal outcomes at five minutes and can be considered clinically acceptable options for induction in obstetric anesthesia. However, clinicians should consider individual patient contexts and institutional protocols when choosing between the agents. Further large-scale studies are recommended to assess other neonatal and maternal outcomes.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。