Abstract

ImmunoCAP ISAC E112i (ISAC) and Allergy Explorer 2 (ALEX(2)) detect specific immunoglobulin E (IgE) reactivity. Both multiplex assays contain molecular allergens and ALEX(2) additionally includes allergen extracts and inhibitors that block the binding of IgE to cross-reacting carbohydrate determinants (CCDs). This study aimed to compare the performance of ISAC and ALEX(2) by determining the IgE reactivity against allergen extracts and/or allergen components and by using qualitative, semiquantitative, and quantitative analyses of all comparable allergen components in sera from 216 participants recruited in South Tyrol/Italy. For extract sensitization in ALEX(2), the analysis revealed negative corresponding allergen components in 18.4% and at least one positive corresponding allergen component in 81.6% of all cases. For ISAC, the corresponding results were 23.5% and 76.5% of cases, respectively. The ALEX(2) CCD inhibitor eliminated CCD-positive signals detected by ISAC in 88.5% of cases. Based on sensitization values of 0.3-14.9 ISU or kU(A)/L, there was good agreement between ALEX(2) and ISAC, although ALEX(2) showed higher values than ISAC. The addition of allergen-extract tests in ALEX(2) resulted in the detection of more sensitizations than with corresponding allergen components alone. In the range of <15 ISU or kU(A)/L, ALEX(2) may be more effective in detecting sensitizations.