Utilizing Leadless Pacemakers in Extremely Elderly Patients With a Conventional Pacemaker System: A Two-Year Follow-Up Case Series Without Generator Extraction in High-Risk Scenarios

在极高龄且已植入传统起搏器系统的患者中使用无导线起搏器:一项为期两年的随访病例系列研究(高风险情况下无需取出起搏器发生器)

阅读:1

Abstract

Background and objectives Leadless pacemakers, known for their safer clinical profile, offer significant advantages for elderly patients at a higher risk of complications associated with transvenous pacemaker procedures, particularly those susceptible to high-risk bleeding and infections related to cardiac implantable electronic device interventions. This study explores an alternative use of leadless pacemakers without removing existing transvenous systems, deviating from conventional generator replacement and lead re-interventions. Methods This study was conducted with full approval from the Institutional Review Board, Medical Ethical Committee, Centro Hospitalar Conde São Januário, Macau. Between January 2018 and December 2021, we conducted a retrospective case series involving extremely elderly individuals (aged 85 years or older) at a high risk of complications, necessitating either generator replacement or lead re-implantation. The study considered implanting a leadless pacemaker (Micra; Medtronic, Minneapolis, MN, USA) without removing the transvenous generator. For the primary endpoints, we evaluated procedure-related complications and clinical outcomes during hospitalization. Secondary endpoints included the stability of parameters and any unexpected interference or interactions between the two systems during the two-year follow-up. Results Eleven patients (aged 86-101) were enrolled, most receiving antiplatelet or anticoagulation therapy. Leadless pacemaker implantation proceeded without major complications or adverse clinical outcomes during hospitalization. Regular follow-up was conducted every three to six months for adjusting pacemaker parameters and interrogating each patient. Over two years, three patients died from non-cardiac causes: two from infection and one from spontaneous intracranial hemorrhage, while eight completed regular follow-ups. We didn't detect any episodes of ventricular arrhythmias or intracardiac capture from the transvenous pacemaker system. We observed the stability in both the longevity and the voltage of the conventional generator battery, maintaining similar parameters without significant depletion (mean voltage decline: -0.07V/year). Parameters of the leadless pacemaker remained consistently normal without interference with existing pacing systems. Conclusion Implanting leadless pacemakers without removing transvenous pacemaker generators appears safe and effective for extremely elderly patients who are at high risk of complications. Comprehensive two-year follow-up supports the safety and viability of this approach. Opting for this approach instead of conventional generator replacement, with or without additional lead implantation, may be reasonable in this population. However, further research within this patient cohort, such as exploring long-term outcomes beyond two years or comparing clinical outcomes with conventional strategies, may be necessary.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。