Evaluation of Surface Roughness of Translucent Zirconia After Applying Nd:YAG and CO2 Lasers: An In Vitro Study

Nd:YAG激光和CO2激光处理后半透明氧化锆表面粗糙度的评价:一项体外研究

阅读:1

Abstract

BACKGROUND AND OBJECTIVES: Surface roughness is one of the most important factors that play an important role in increasing the connection between the surface of the tooth and the applied restoration. Due to the increased interest in zirconia and the improvement of its mechanical and aesthetic properties, studies have increased that work to improve and increase its surface roughness so that it can be used as a veneer in the future. This study aims to compare the effect of two types of lasers on the surface of highly transparent zirconia to evaluate the surface roughness resulting from the two techniques. METHODOLOGY: The study sample consisted of 20 ceramic cubes made of translucent zirconia (DD cubeX2, Dental Direct, Germany). It was made using a CAD-CAM Zircodenta device (Imes-Icore, Germany) and a zirconia sintering furnace (Imes-Icore, Germany). The study sample was divided into two groups; the first group consisted of 10 cubes exposed to Nd:YAG laser and the second group consisted of 10 discs exposed to continuous wave CO(2) laser. The surface roughness test was conducted for the study samples in each of the groups using a surface roughness tester. Data were collected and analyzed using SPSS v25 software. RESULTS: The surface roughness was measured and its mean was 1.208±0.22 in the Nd:YAG laser group and 0.809±0.21 in the CO(2) laser group. There was a significant difference between the study groups according to the independent sample T-test. CONCLUSION: This study concluded that the Nd:YAG laser surface roughens of zirconia is greater than the continuous wave CO(2) laser, with a substantially significant difference.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。