Multi-objective optimization and 4E (energy, exergy, economy, environmental impact) analysis of a triple cascade refrigeration system

三级复叠制冷系统的多目标优化和4E(能量、㶲、经济性、环境影响)分析

阅读:1

Abstract

The post-pandemic energy crisis and ever-increasing environmental degradation necessitate researchers to scrutinize refrigeration systems, major contributors to these issues, for minimal environmental impact and maximum performance. Thus, this study aims to comprehensively examine a triple cascade refrigeration system (TCRS) equipped with hydrocarbon refrigerants (1-butene/Heptane/m-Xylene). This system is specifically designed for ultra-low temperature applications, including vaccine storage, quick-freezing, frozen food preservation, cryogenic processes, and gas liquefaction. The investigation integrates conventional thermodynamic analysis with economic and environmental impact assessments, and finally multi-objective optimization (MOO) to ascertain optimal operating conditions for the system. The effect of (1) evaporator temperature, T(evap) (2) condenser temperature, T(cond) (3) Lower Temperature Circuit (LTC) condenser temperature, T(LTC) (4) Mid Temperature Circuit (MTC) condenser temperature, T(MTC) and (5) Cascade Condenser temperature difference, ΔT on three objective functions (COP, exergy efficiency, and overall plant cost) have been investigated employing a parametric analysis. Subsequently, quadratic equations for these objective functions are generated using the Box-Behnken method, and MOO utilizing the Genetic algorithm has been performed to maximize COP and exergy efficiency while minimizing the overall cost rate. The decision-making techniques TOPSIS and LINMAP are used to retrieve a unique solution from the Pareto Front, and the system performance has been assessed at the optimal point. The optimization result demonstrates that for the 10-kW capacity TCRS, COP, exergy efficiency, and total plant cost are 0.71, 0.51, and 38262.05 $/year respectively, at optimum condition (T(evap) = -101.023 °C , T(cond) = 36.545 °C , T(LTC) = - 69.047 °C and T(MTC) = - 34.651 °C ). Exergy analysis identifies HTC compressor (19.3 %) and throttle valve (15.5 %) as key contributors to total exergy destruction, while economic analysis underscores capital and maintenance costs (72 %) as the primary contributors to the overall cost, with evaporator (43 %) and condenser (20 %) accounting for 63 % of this cost.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。