Interaction energy flow paths analysis of PMSG-based wind power integrated systems during LVRT and its parameter adjustment strategy

基于永磁同步发电机的风力发电并网系统在低电压穿越过程中的交互能量流路径分析及其参数调整策略

阅读:1

Abstract

To solve the problem of oscillation instability in permanent magnetic synchronous generator (PMSG)-based wind power connected systems during low-voltage ride through (LVRT) process, a parameter adjustment strategy based on interaction energy path optimization is proposed in this paper. Firstly, a modular state-space model of PMSG under fault transient conditions is constructed, and the system is divided into five subsystems. Then, the dynamic energy function of subsystems reflecting the oscillation stability of the system is derived. Based on that, the dynamic energy flow path is described considering the introduction of LVRT control. On this basis, the interaction energy between LVRT control links and subsystems is analyzed, and the coupling mechanism of voltage support and damping characteristics in the LVRT process is explained. Further, aiming at the optimal change rate of the total interaction energy in the LVRT process, the adjustment strategy of LVRT control parameters is constructed to meet voltage and damping requirements. Finally, a PMSG-connected system model is built on the MATLAB/Simulink platform to verify the effectiveness of the adjustment strategy. The results show that the proposed method can effectively improve the damping level under the fault transient condition, as well as supporting system voltage.