Embolization of an arteriovenous malformation using the "pressure cooker" technique in the AICA via a marathon microcatheter: A case report

经马拉松微导管采用“压力锅”技术栓塞小脑前下动脉动静脉畸形:病例报告

阅读:1

Abstract

INTRODUCTION AND IMPORTANCE: Embolization of an arteriovenous malformation (AVM) via the anterior inferior cerebellar artery (AICA) is difficult. The "pressure cooker" technique in the AICA via a marathon microcatheter can be effective. CASE STUDY: A 43-year-old man with a cerebellar hematoma involving the brainstem. Angiography revealed an AVM supplied by the right AICA. Embolizing the AVM by casting an Onyx-18 liquid embolic system assisted by the "pressure cooker" technique was planned. An Apollo microcatheter was used for Onyx casting, and a Marathon microcatheter was used to establish a coiling plug to prevent Onyx reflux. The AVM was obliterated. Postoperatively, burr hole drainage of the cerebellar hematoma was performed. Postoperative computed tomography showed that the cerebellar hematoma and hydrocephalus had resolved. Magnetic resonance imaging revealed that there was no new serious infarction from damage to the cerebellum or brainstem. The patient recovered well. CLINICAL DISCUSSION: During Onyx casting, the drawback is that reflux can occlude normal vessels. The "pressure cooker" technique was useful for preventing Onyx reflux and for driving the Onyx to penetrate the AVM. However, it was difficult to use this technique in slim AICA; the Marathon microcatheter had a thinner tip than other microcatheters, and it can be used to establish the "pressure cooker" technique. This technique provides more solutions for AVMs in transarterial embolization through small feeding arteries. CONCLUSION: In a selective case, it was feasible to use the "pressure cooker" technique in the AICA via a Marathon microcatheter to embolize the AVM.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。