Endovascular salvage of renal and common iliac artery malperfusion following inadvertent hybrid arch dissection stent deployment in the false lumen during repair of type A dissection

在A型主动脉夹层修复术中,因意外将混合型主动脉弓夹层支架置入假腔而导致肾动脉和髂总动脉灌注不良,需进行血管内挽救治疗。

阅读:1

Abstract

This case report describes the endovascular management of a hybrid arch dissection stent inadvertently deployed in the false lumen during acute type A aortic dissection repair, resulting in renal and lower extremity malperfusion. Prompt identification and intervention are essential to minimize the morbidity and mortality associated with malperfusion. Various endovascular strategies exist to restore perfusion, and this case highlights a unique approach given the obliteration of the true lumen proximally and anatomy of the visceral ostia predominantly originating from the false lumen.