Standardized approach for four-fenestrated physician-modified endograft to treat complex abdominal aortic aneurysms using Valiant Captivia

采用 Valiant Captivia 治疗复杂腹主动脉瘤的标准化方法,使用四孔医生改良型血管内移植物。

阅读:1

Abstract

We describe the feasibility and safety of a standardized approach for four-fenestrated physician-modified endograft (PMEG) placement to treat complex abdominal aortic aneurysms using the Valiant Captivia platform (Medtronic). The standardization is based on specific selection criteria for anatomical feasibility, measurement method, and modification technique of a single endograft type. Six cases (two juxtarenal, two pararenal, and two type IV thoracoabdominal aneurysms) were treated, with 24 target vessels incorporated with fenestrations. Four cases were treated in an urgent setting and two were elective. The time modification required was 121 ± 18 minutes. Technical success was 100%, with no mortality or complications at 30 days. Postoperative computed tomography at 3 months demonstrated complete aneurysm exclusion, without a type I or III endoleak, no main graft- or fenestration-related loss of integrity, and no target vessel misalignment or stent fracture. The present standardized approach seems safe and feasible and might represent an initial benchmark for comparison with future studies.