Prediction of fluid responsiveness in spontaneously breathing patients with hemodynamic stability: a prospective repeated-measures study

预测自主呼吸且血流动力学稳定的患者的液体反应性:一项前瞻性重复测量研究

阅读:1

Abstract

Evaluating fluid responsiveness with dynamic parameters is recommended for fluid management. However, in hemodynamically stable patients who are breathing spontaneously, accurately measuring stroke volume variation via echocardiography and passive leg raising is challenging due to subtle SV changes. This study aimed to identify normal SV changes in healthy volunteers and evaluate the precision of hemodynamic parameters in screening mild hypovolemia in patients. This prospective, repeated-measures, cross-sectional study screened 269 subjects via echocardiography. Initially, 45 healthy volunteers underwent a fluid challenge test, the outcomes of which served as criteria to screen 215 ICU patients. Among these patients, 53 underwent additional fluid challenge testing. Hemodynamic parameters, including medians of maximum velocity time integrals (VTImaxs), peak velocity of VTImax (PV), internal jugular vein diameters (IJVD), and area (IJVA) were repeatedly measured first at a 60° upper body elevation (UBE), second in a supine position, third at UBE, fourth in a supine position, and lastly in a supine position after fluid loading. The hemodynamic responses to the position changes were compared between 83 fluid non-responders and 15 fluid responders. Fluid responsiveness was defined as fluid-induced medians' change of VTImaxs (fluid-induced median VTImax change) ≥ 10%. None of the healthy volunteers showed the mean value of repeatedly measured medians of VTImaxs ≥ 7%, following either UBE position (UBE-induced median VTImax change) or fluid loading (fluid-induced median VTImax change). UBE-induced median VTImax and PV changes were significantly correlated with fluid responsiveness (p < 0.001, AUC 0.959; p < 0.001, AUC 0.804). The significant correlations were demonstrated via multivariable analysis using binary logistic regression (p = 0.001, OR 90.1) and the correlation coefficient (R(2) = 0.793) using linear regression analysis. UBE-induced median VTImax changes (≥ 11.8% and 7.98%) predicted fluid-induced median VTImax changes ≥ 10% and 7% (AUC 0.959 and 0.939). The collapsibility and variation of IJVD and IJVA showed no significant correlation. An increase in the mean value of medians of repeatedly measured VTImaxs transitioning from an UBE to a supine position, effectively screened mild hypovolemia and demonstrated a significant correlation with fluid responsiveness in spontaneously breathing patients maintaining hemodynamic stability.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。