3D Printer-Assisted Layered Fabrication of a Novel Appliance for Oral Myofunctional Therapy and Functional Evaluation of Its Effects on Orofacial Muscles During Wear

利用3D打印辅助分层制造一种新型口腔肌功能治疗装置,并评估其佩戴过程中对口面部肌肉的影响

阅读:1

Abstract

Aim Balanced function of the orofacial muscles is important for normal occlusion and dentition; however, patients with malocclusion often present with myofunctional disorder (MFD). Myofunctional therapy (MFT) has received much attention as a method for reducing MFD. Moreover, prefabricated functional appliances (PFAs) have been developed as a method to eliminate abnormal muscle pressure and guide the tongue into the correct position. However, PFAs have disadvantages, such as poor intraoral retention, limited usage time due to discomfort and poor patient compliance, and changes in the axis of the mandibular anterior teeth. Therefore, this study aimed to develop a new custom-made splint-type orthodontic appliance with CAD/CAM technology. Moreover, we evaluated the characteristics of the appliance and conducted functional tests to determine the effects of the appliance on the orofacial muscles and the discomfort associated with its use. Materials and methods Twenty-five volunteers (nine females and 16 males; mean age 28.4 ± 3.4 years) with normal swallowing function were included in the study. Lip-closing strength (LCS), electromyogram during swallowing, oxygen saturation, and pulse rate were measured and compared when the appliance was not worn and when it was worn. In addition, tongue habits were evaluated, and the maximum tongue pressure was measured when the appliance was not worn. The subjects were asked to answer a questionnaire using a numerical rating scale (NRS) regarding discomfort when wearing the appliance. The evaluation items were swallowing difficulty, speaking difficulty, and breathlessness, which were rated on an 11-point scale ranging from 0 to 10. Statistical tests were conducted using IBM SPSS version 28.0.1 (IBM, Armonk, NY, USA) with the Shapiro-Wilk and Levene's test, followed by the Wilcoxon signed rank sum test. The significance level was set at α = 0.05. The measurement error for each measurement item was evaluated using an intraclass correlation coefficient. Results A new custom-made splint-type orthodontic appliance was fabricated for each subject. The fit and retention of the appliance in the mouth were good when fitted, and a comparison of the functional test measurements of 25 subjects with and without the appliance showed that the LCS decreased significantly (p<0.05) before and after wearing the appliance. However, no statistically significant differences were found for the other items. The Mann-Whitney U test regarding the effects of sex, previous orthodontic treatment, or MFT, and oral habits did not statistically significantly influence the effects of wearing the device. In the NRS results, "difficulty swallowing" was observed in half of the subjects, "difficulty breathing" was rarely observed, and "difficulty speaking" was observed in all subjects. Conclusions A novel custom-made splint-type orthodontic appliance was designed and fabricated using digital workflow and 3D printing technology. This appliance was designed to correct oral habits and was made from a new material classified as a class II medical appliance according to the international harmonized classification.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。