In Situ Monitoring of Anodic Acidification Process Using 3D μ-XCT Method

利用三维μ-XCT方法对阳极酸化过程进行原位监测

阅读:1

Abstract

Debonding of the primary anode caused by anodic acidification is one of the major failure modes of the impressed current cathodic protection (ICCP) system in reinforced concrete structures. This study used 3D micro X-ray computed tomography (μ-XCT) to monitor the in situ evolution of the anodic acidification-affected zone. Samples were scanned after 0 to 40 days of the accelerated anodic acidification test. The anodic acidification-affected zone was identified in μ-XCT images using the gray level segmentation method. The total volume of this zone was measured using the 3D reconstruction method. It was found that detailed 3D information can be extracted using the 3D reconstruction method. The spatial heterogeneity was analyzed using this reconstructed volume information. The Faraday efficiency was calculated and found to increase after 20 days of operation. It was also found that the affected zone was proportional to the input electrical energy. The proposed model is useful for estimating the durability of an ICCP system.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。