Comparative Evaluation of Clinical Outcome Including Neurosensory Deficit and Pain Score Variables Using Rigid Internal Fixation with Three-Dimensional Miniplate Internal Fixation in Simultaneous Angle and Contralateral Body/Parasymphysis Fractures of the Mandible: A Prospective, Randomized Controlled Study

比较刚性内固定与三维微型钢板内固定治疗下颌角及对侧下颌体/颏旁骨折的临床疗效(包括神经感觉障碍和疼痛评分)的前瞻性随机对照研究

阅读:1

Abstract

Purpose  There have been numerous advancements in the strategies used for treating mandibular fractures in the present times, while open reduction and internal fixation is still accepted as the most preferred treatment option for such fractures despite numerous drawbacks. The aim of the present prospective, randomized controlled study was to evaluate the clinical outcome including neurosensory deficit and pain score variables in mandibular fractures that were treated using rigid internal fixation with three-dimensional (3D) miniplate internal fixation. Materials and Methods  For the present study, a total of 20 patients of either sex in an age range of 18 to 55 years with simultaneous angle and contralateral body/parasymphysis fractures of the mandible were included, while the clinical outcome was compared in relation to the two groups wherein different treatment options were used including using rigid internal fixation in one as against 3D miniplate internal fixation in the other. Results  Pairwise comparison of pain scores in Group I and Group II patients by the Mann-Whitney U-test at different time zones revealed the results to be statistically significant for all pairs except when the findings were compared between 1 month and 3 months after the procedure in Group II patients. Also, significant recovery was observed in both Group I and II patients during healing when assessed preoperatively to 1 month and then 3 months after the procedure with the results being statistically highly significant in case of the variations observed in relation to the neurosensory deficit observed at different time zones for both Group I and II patients ( p  = 0.0001). Conclusion  Based on the results obtained, it can be concluded that 3D miniplate-led osteosynthesis was found comparable to the osteosynthesis accomplished using reconstruction plates during fixation of unfavorable body/parasymphysis fractures of mandible in study, providing optimal stability, while satisfactorily meeting the biomechanical requirements for occlusal loading, and an early return to normal function.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。