Effect of in-line filtration in newborns: study protocol of the Intravenous Neonatal Central Access Safety (INCAS) randomized controlled trial

在线过滤对新生儿的影响:新生儿静脉中心通路安全性(INCAS)随机对照试验的研究方案

阅读:1

Abstract

BACKGROUND: Particulate contamination due to infusion therapy (administration of parenteral nutrition and medications) carries a potential health risk for infants in neonatal intensive care units (NICUs). This particulate consists of metals, drug crystals, glass fragments, or cotton fibers and can be generated by drug packaging, incomplete reconstitution, and chemical incompatibilities. In-line filters have been shown to remove micro-organisms, endotoxin, air, and particles in critically ill adults and older infants, but its benefits in newborn remain to be demonstrated. Moreover, 50% of inflammatory episodes in the setting of NICUs are blood culture-negative. These episodes could be partly related to the presence of particles in the infusion lines. METHODS: A multicenter randomized single-blind controlled trial was designed. All infants admitted to NICUs for which prolonged infusion therapy is expected will be enrolled in the study and randomized to the Filter or Control arm. All patients will be monitored until discharge, and data will be analyzed according to a "full analysis set." The primary outcome is the frequency of patients with at least one sepsis-like event, defined by any association of suspected sepsis symptoms with a level of c-reactive protein (CRP) > 5 mg/L in a negative-culture contest. The frequency of sepsis, phlebitis, luminal obstruction, and the duration of mechanical ventilation and of catheter days will be evaluated as secondary outcomes. The sample size was calculated at 368 patients per arm. DISCUSSION: This is the first multicenter randomized control trial that compares in-line filtration of parenteral nutrition and other intravenous drugs to infusion without filters. Sepsis-like events are commonly diagnosed in clinical practice and are more frequent than sepsis in a positive culture contest. The risk of these episodes in the target population is estimated at 30-35%, but this data is not confirmed in the literature. If the use of in-line filters results in a significant decrease in sepsis-like events and/or in any other complications, the use of in-line filters in all intravenous administration systems may be recommended in NICUs. TRIAL REGISTRATION: ClinicalTrials.gov, NCT05537389, registered on 12 September 2022 ( https://classic. CLINICALTRIALS: gov/ct2/show/results/NCT05537389?view=results ).

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。