Model-based prototype design, establishment and operation of ventilation system for underground gymnasium

基于模型的地下体育馆通风系统原型设计、建立和运行

阅读:1

Abstract

Underground small indoor gymnasiums (USIG) are important public places, it is vital to design and build a very economical and efficient ventilation system for effective closed-loop regulation of temperature and gases concentration at prescribed levels. In the article, the model-based prototype design, establishment and operation were proposed and applied to closed-loop control system of the underground small indoor gymnasiums' ventilation system (USIGVS). First of all, the extended Multiphysics model was developed through feedback connecting the 3D Multiphysics model of air flow rate, temperature, O(2) and CO(2) concentration with a 0D proportional-integral-derivative (PID) controller via Neumann boundary condition, hence a close-loop USIGVS was constructed for feedback control of temperature and gases concentration in ping-pong USIG. Simultaneously, a cost function sufficiently representing the design requirement was formulated. Then global parameter sensitivity analysis (GPSA) was applied for sensitivity ranking of parameters including geometric parameters of USIGVS and tunable parameters of PID controller. The GPSA proved that sensitivity ordering of the cost function to each parameter was proportional gain (k (p) ) > derivative gain (k (d) ) > distance from left inlet to bottom (r) > distance from outlet pipe to bottom (d) > integrative gain (k (i) ) > distance from upper inlet pipe to left (h), respectively, and the k (p) , k (d) and r was the parameter influencing the cost function the most. The optimal parameters determined by both GPSA and response optimization were k (p) = 3.17 m(4) mol(-1) s(-1), k (d)  = 1.49 m(4) mol(-1), r = 2.04 m, d = 3.12 m, k (i)  = 0.37 m(4) mol(-1) s(-2) and h = 3.85 m. Finally, the closed-loop USIGVS prototype with optimal parameters was designed and established through real-time simulation. The real-time operation confirmed that the temperature and gases concentrations were robust maintained at prescribed levels with desired dynamic response characteristics and lower power consumption, and the expected requirements were achieved for the design, establishment and operation of closed-loop USIGVS control system prototype.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。