Use of a poll-mounted accelerometer for quantification and characterisation of equine trigeminal-mediated headshaking

利用安装在马头上的加速度计对马三叉神经介导的摇头行为进行量化和表征

阅读:1

Abstract

BACKGROUND: Equine trigeminal-mediated (TGM) headshaking (HS) is a neuropathic facial pain syndrome characterised by varying intensity and frequencies of head movements and signs of nasal irritation. An accurate method for quantification and/or characterisation of HS severity is lacking. OBJECTIVES: To develop and validate an objective measure of TGMHS. STUDY DESIGN: Prospective case control study. METHODS: Horses presenting for investigation of HS were recruited alongside those presenting for forelimb lameness (LAME) and pre-purchase examination as well as healthy controls (CONTROL). Head movement data were collected for 5 min whilst trotting on the lunge using a tri-axial accelerometer, with a range of ±16 g and sampling rate of 800 Hz, attached to the bridle headpiece. Recordings were exported for processing. Peak detection was performed using minimum and maximum thresholds of -1 g and +1 g (corrected for gravity) and a minimum peak width of 10 samples. RESULTS: Fifty-six horses were included in the study; 18 TGMHS, 10 non-TGMHS, 12 LAME and 16 CONTROL. Characteristics and frequency of vertical (Z axis) head movements of TGMHS horses differed significantly from other horses. TGMHS horses had peaks with greater mean and maximum positive g-force (P < 0.005) and lower mean and minimum negative g-force (P < 0.001), greater frequency of peaks/min (P < 0.001) and over 12 times greater percentage of peaks >+2 g compared with other horses (P < 0.001). Receiver operator curve characteristics of percentage of peaks >+2 g (CI 0.72-0.95), percentage of peaks <-2 g (CI 0.66-0.92) and percentage of peaks <-2 g and >+2 g (CI 0.72-0.96) showed excellent discrimination of TGMHS horses from LAME, CONTROL and non-TGMHS horses. MAIN LIMITATIONS: Referral population of horses, small sample size and control horses were not evaluated for orthopaedic disease. CONCLUSIONS: Accelerometer data from trotting exercise on the lunge provides an objective measure of HS and can differentiate between TGMHS, non-TGMHS, normal head movements and those associated with forelimb lameness. Accelerometer use may aid HS diagnosis and monitoring of management strategies.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。