Assessing Accumulation of Organic Material on Rodent Cage Accessories

评估啮齿动物笼具配件上有机物的积累情况

阅读:1

Abstract

According to the 8th edition of the Guide for the Care and Use of Laboratory Animals (the Guide), rodent cage accessories, such as filter tops, should be sanitized at least once every 2 wk. We performed a study to test the hypothesis that organic contamination (measured by ATP content, expressed as relative light units (RLU)) of cage accessories (wire bar inserts and filter top lids) does not differ at 2 wk (14 d) as compared with 30, 60, and 90-d time points after cage change even when in constant use. An additional time point for filter top lids of 180 d after cage change was also evaluated. Eight groups were studied: the wire bar inserts and filter top lids used for mice and rats, in both static and individually ventilated cages (IVC). When analyzing data from both mouse and rat static and IVC caging, we found that the mean RLU values for mouse IVC and rat static and IVC cage components were below 100,000 RLU at the 14-d time point. The mean value for the mouse static group was slightly above 100,000 RLU at this time point. Based on this observation, we considered 100,000 RLU to be an appropriate actionable level. We concluded that changing wire bar inserts at least every 14 d, as recommended in the Guide for sanitizing these components in mouse and rat static cages, may be considered acceptable. This interval could be extended for mouse and rat IVC cages up to 90 d while remaining below this limit. Filter top lids for mouse static cages should be changed at least every 30 d, but static rat and IVC mouse/rat filter top lids could be changed up to every 180 d, while still staying below this actionable level of contamination.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。