Bio-Electroanalysis Performance of Heme Redox-Center for π- π Interaction Bonding of a Methylene Blue-Graphene Modified Electrode

血红素氧化还原中心π-π相互作用对亚甲蓝-石墨烯修饰电极的生物电分析性能

阅读:7
作者:Porntip Khownarumit, Kanmanee Choosang, Rungtiva P Poo-Arporn, Yingyot Poo-Arporn, Narong Chanlek, Werasak Surareungchai

Abstract

Hemeprotein detection has motivated extensive research on the direct reaction of a heme molecule and a redox dye. The present study used methylene blue as both donor and acceptor for a redox reaction. First, the solid phases of methylene blue (MB) and graphene (GP) formed a π-π interaction bond at the aromatic rings. The conductivity of GP was better than that of carbon in a carbon electrode (CE). Then, the working CE was modified using strong adsorption of MB/GP on the electrode surface. The surface of the electrode was investigated using a modified and an unmodified electrode. The electrode's properties were studied using voltammograms of redox couple K3[Fe(CN)6]3-/4-. Its reaction was used to find the active area of the modified electrode, which was 1.76 times bigger than that of the unmodified electrode. The surface coverage values of the modified and unmodified electrodes were 8.17 × 10-6 and 1.53 × 10-5 mol/cm2, respectively. This research also studied the application of hemeprotein detection. Hemoglobin (Hb), myoglobin (Mb), and cytochrome c (Cyt. C) were studied by the reaction of Fe (III/II) at the heme-redox center. The electrocatalytic reaction between MB/GP and hemeproteins produced an anodic peak at 0.35 V for Hb, Mb, and Cyt. C. This nanohybrid film enhanced electron transfer between protein molecules and the modified carbon electrode. The amperometric measurements show that the limit of detection was 0.2 µM, 0.3 µM, and 0.1 µM for Hb, Mb, and Cyt. C, respectively. The measurement spanned a linear range of 0.2 µM to 5 µM, 0.3 µM to 5 µM, and 0.1 µM to 0.7 µM for Hb, Mb, and Cyt. C, respectively. Hb showed the lowest sensitivity compared with Mb and Cyt. C due to the role of steric hindrance in the hemeprotein specificity structure. This study offers a simple and efficient fabrication platform for electrochemical sensors for hemeproteins. When compared to other complex immobilization processes, the fabrication method for this sensor has many benefits, including no need for special chemicals and easy preparation and electrode modification-both of which are crucial for the development of electrochemical sensing devices.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。