Minimally Invasive SI Joint Fusion Procedures for Chronic SI Joint Pain: Systematic Review and Meta-Analysis of Safety and Efficacy

治疗慢性骶髂关节疼痛的微创骶髂关节融合术:安全性和有效性的系统评价和荟萃分析

阅读:6
作者:Peter G Whang, Vikas Patel, Bradley Duhon, Bengt Sturesson, Daniel Cher, W Carlton Reckling, Robyn Capobianco, David Polly

Background

Sacroiliac (SI) joint fusion is increasingly used to treat chronic SI joint pain. Multiple surgical approaches are now available.

Discussion

Literature support for SI joint fusion is growing. The LTI procedure contains the largest body of available evidence and shows the largest improvements in pain and ODI. Only LTI procedures have independent radiographic evidence of fusion and implant placement. The adverse event rate for all procedures was low.

Methods

Data abstraction and random effects meta-analysis of safety and efficacy outcomes from published patient cohorts. Patient-reported outcomes (PROs) and safety measures were stratified by surgical technique: transiliac, including lateral transiliac (LTI) and posterolateral transiliac (PLTI), and posterior interpositional (PI) procedures.

Results

Fifty-seven cohorts of 2851 patients were identified, including 43 cohorts (2126 patients) for LTI, 6 cohorts (228 patients) for PLTI, and 8 cohorts (497 patients) for PI procedures. Randomized trials were only available for LTI. PROs were available for pain (numeric rating scale) in 57 cohorts (2851 patients) and disability (Oswestry Disability Index [ODI]) in 37 cohorts (1978 patients).All studies with PROs showed improvement from baseline after surgery. Meta-analytic improvements in pain scores were highest for LTI (4.8 points [0-10 scale]), slightly lower for PLTI (4.2 points), and lowest for PI procedures (3.8 points, P = 0.1533). Mean improvements in ODI scores were highest for LTI (25.9 points), lowest for PLTI procedures (6.8 points), and intermediate for PI (16.3 points, P = 0.0095).For safety outcomes, acute symptomatic implant malposition was 0.43% for LTI, 0% for PLTI, and 0.2% for PI procedures. Wound infection was reported in 0.15% of LTI, 0% of PLTI, and 0% of PI procedures. Bleeding requiring surgical intervention was reported in 0.04% of LTI procedures and not reported for PLTI or PI. Breakage and migration were not reported for any device. Radiographic imaging evaluation reporting implant placement accuracy and fusion was only available for LTI.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。