Application of a novel deep eutectic solvent modified carbon nanotube for pipette-tip micro solid phase extraction of 6-mercaptopurine

新型深共晶溶剂修饰碳纳米管用于 6-巯基嘌呤吸头微固相萃取的应用

阅读:11
作者:Leila Raisi, Sayyed Hossein Hashemi, Ahmad Jamali Keikha, Massoud Kaykhaii

Background

6-mercaptopurine (6-MP) is a chemotherapy drug mainly used to treat leukemia. It is a persistent organic pollutant and can remain in the environment for a long period of time. The presence of 6-MP in the environment poses a number of hazards and needs to be assessed to monitor its potential risk to human health and the environment. However, due to its trace amount in complicated matrices, a clean-up and preconcentration step before its determination is compulsory.

Conclusion

Application of deep eutectic solvent modified carbon nanotube indicated suitable microextraction results and good potential for rapid extraction of trace amounts of 6-MP from different aqueous samples. The amount of sample required for the analysis was less than 10 mL and only 1.5 mg of the adsorbent was used. The total analysis time, including extraction was less than 15 min and the adsorbent could be used for at least 10 times, without significantly losing its adsorption ability. Compared to using unmodified usual carbon nanotubes, deep eutectic solvent doped carbon nanotubes showed 19.8% higher extraction ability.

Results

As a highly efficient adsorbent for the extrication of 6-mercaptopurine (6-MP), a novel carbon nanotube doped with camphor: decanoic acid deep eutectic solvent was synthesized and applied as a packing material for the pipette-tip micro solid phase extraction sorbent of 6-MP from tap, wastewater and seawater samples before its spectrophotometric determination. Characteristics and structure of this adsorbent was fully investigated. Factors affecting extraction, including type and volume of the eluent, ionic strength and pH of the sample solution, amount of adsorbent, and number of extraction and elution cycles were optimized using one-factor-at-a-time and response surface methodologies. The method was found to be linear in the range of 1 to 1000 µg/L with a limit of detection and quantification of 0.2 and 0.7 µg/L, respectively. Reproducibility as relative standard deviation was better than 4.6%.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。