Levofloxacin pharmacokinetics in saliva as measured by a mobile microvolume UV spectrophotometer among people treated for rifampicin-resistant TB in Tanzania

使用移动微量紫外分光光度计测量坦桑尼亚接受利福平耐药结核病治疗的人群唾液中的左氧氟沙星药代动力学

阅读:5
作者:Sagal Mohamed, Happiness C Mvungi, Margaretha Sariko, Prakruti Rao, Peter Mbelele, Erwin M Jongedijk, Claudia A J van Winkel, Daan J Touw, Suzanne Stroup, Jan-Willem C Alffenaar, Stellah Mpagama, Scott K Heysell

Background

Early detection and correction of low fluoroquinolone exposure may improve treatment of MDR-TB. Objectives: To explore a recently developed portable, battery-powered, UV spectrophotometer for measuring levofloxacin in saliva of people treated for MDR-TB.

Conclusions

Portable UV spectrophotometry as a point-of-care screen for subtarget levofloxacin exposure was feasible. Use for triage to other investigation or personalized dosing strategy should be tested in a randomized study.

Methods

Patients treated with levofloxacin as part of a regimen for MDR-TB in Northern Tanzania had serum and saliva collected concurrently at 1 and 4 h after 2 weeks of observed levofloxacin administration. Saliva levofloxacin concentrations were quantified in the field via spectrophotometry, while serum was analysed at a regional laboratory using HPLC. A Bayesian population pharmacokinetics model was used to estimate the area under the concentration-time curve (AUC0-24). Subtarget exposures of levofloxacin were defined by serum AUC0-24 <80 mg·h/L. The study was registered at Clinicaltrials.gov with clinical trial identifier NCT04124055.

Results

Among 45 patients, 11 (25.6%) were women and 16 (37.2%) were living with HIV. Median AUC0-24 in serum was 140 (IQR = 102.4-179.09) mg·h/L and median AUC0-24 in saliva was 97.10 (IQR = 74.80-121.10) mg·h/L. A positive linear correlation was observed with serum and saliva AUC0-24, and a receiver operating characteristic curve constructed to detect serum AUC0-24 below 80 mg·h/L demonstrated excellent prediction [AUC 0.80 (95% CI = 0.62-0.94)]. Utilizing a saliva AUC0-24 cut-off of 91.6 mg·h/L, the assay was 88.9% sensitive and 69.4% specific in detecting subtarget serum AUC0-24 values, including identifying eight of nine patients below target. Conclusions: Portable UV spectrophotometry as a point-of-care screen for subtarget levofloxacin exposure was feasible. Use for triage to other investigation or personalized dosing strategy should be tested in a randomized study.