FIMEC Test to Evaluate the Water Uptake of Coated and Uncoated CFRP Composites

FIMEC 测试评估涂层和未涂层 CFRP 复合材料的吸水率

阅读:5
作者:Francesco David, Patrizia Moretti, Vincenzo Tagliaferri, Federica Trovalusci

Abstract

This study focuses on the application of the FIMEC (flat-top cylinder indenter for mechanical characterization) indentation test to evaluate the effect of water uptake on the mechanical properties of high-performance materials, in particular CFRP (carbon fibre reinforced polymer) composites. Coated and uncoated samples were analyzed. Silicon-based and siloxane coatings were formulated and applied to CFRP to reduce the moisture absorption of the material. The FIMEC test was adopted to study the reduction of the stiffness of CFRP plates for different ageing in water. The evolution of mechanical properties is reported as a function of the water uptake. IR analyses and weight variation measures were used as supporting data. Experimental results show that the FIMEC test is suitable to assess the stiffness reduction due to the aging in water and to identify coatings able to minimize the water uptake.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。