Prepared omadacycline for injection: Nine-day stability and sterility in an elastomeric pump

制备好的注射用奥玛环素:在弹性泵中的九天稳定性和无菌性

阅读:14
作者:Jason Bower, Kelly Wright, Jason Burdette

Conclusion

After reconstitution, omadacycline for injection was stable and remained within specifications for use for up to 9 days when refrigerated.

Methods

Omadacycline was reconstituted to 1 mg/mL with sodium chloride 0.9% w/v or dextrose 5% w/v in SMARTeZ® elastomeric infusion pumps and refrigerated for up to 9 days. Samples were taken daily and tested for appearance, pH, osmolality, chemical composition, and particulate matter. For a microbial challenge study, the pumps were spiked with a challenge microorganism (Staphylococcus aureus, Escherichia coli, Pseudomonas aeruginosa, Candida albicans, or Aspergillus brasiliensis) and samples were plated daily for 9 days to assess microbial survival.

Objective

To investigate compatibility, stability, and microbiologic risk of omadacycline 1 mg/mL when prepared in an elastomeric infusion pump and stored under refrigeration for 9 days based upon requests for information from healthcare providers.

Results

Appearance, pH, osmolality, percent label claim, and particulate matter results remained essentially unchanged for omadacycline solutions in either diluent over the 9-day study. No > 0.5-log day-to-day increases in the challenge-microorganism populations were measured in diluted omadacycline pumps or positive controls. With omadacycline, no growth was seen for S. aureus or E. coli in either diluent, nor for P. aeruginosa in dextrose 5% w/v. Reduction of C. albicans and A. brasiliensis populations over time was similar between omadacycline solutions and positive controls.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。