Ultra-Performance Liquid Chromatography-Tandem Mass Spectrometry for Simultaneous Determination of Antipsychotic Drugs in Human Plasma and Its Application in Therapeutic Drug Monitoring

超高效液相色谱-串联质谱法同时测定人血浆中的抗精神病药物及其在治疗药物监测中的应用

阅读:7
作者:Yingjie Qi, Guangxuan Liu

Conclusion

The results provided significant information to support future clinical TDM and rational drug use research. The proposed method also provided a simple, reliable, specific, and suitable technique for TDM and pharmacokinetic studies.

Methods

Analytes and internal standards (ISs) were separated using a Phenomenex phenyl-hexyl column (50.0 × 2.1 mm, 1.7 μm) with water containing 0.1% formic acid and 2 mM ammonium acetate, and methanol containing 0.1% formic acid and 2 mM ammonium acetate as the mobile phase. The antipsychotic drugs and ISs were extracted from 50 μL of plasma using acetonitrile.

Purpose

We developed and validated an ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method for simultaneous therapeutic drug monitoring (TDM) and clinical pharmacokinetic antipsychotic drugs: clozapine (CLP), chlorpromazine (CPZ), risperidone (RPD), paliperidone (PLD), quetiapine (QTP;), aripiprazole (APZ), dehydroaripiprazole (DAP), olanzapine (OZP), ziprasidone (ZRD), and amisulpride (ASP).

Results

The calibration ranges were 25.0-1500.0 ng/mL for CLP, CPZ, DAP, and QTP, 10.0-600.0 ng/mL for CPZ and ZRD, 2.5-150.0 ng/mL for RPD, 5.0-300.0 ng/mL for PLD and OZP, and 20.0-1200.0 ng/mL for ASP. Validation was carried out according to the guidelines for bioanalytical validation, including assessment of calibration curves, specificity, accuracy, precision, recovery, stability, dilution integrity, and matrix effect. All the results satisfied the requirements.