Precise analysis of single small extracellular vesicles using flow cytometry

利用流式细胞术对单个微小细胞外囊泡进行精确分析

阅读:1
作者:Hisano Kobayashi # ,Takayuki Shiba # ,Takeshi Yoshida ,Dilireba Bolidong ,Koroku Kato ,Yoshiki Sato ,Mao Mochizuki ,Takafumi Seto ,Shuichi Kawashiri ,Rikinari Hanayama

Abstract

Methods that enable specific and sensitive quantification of small extracellular vesicles (sEVs) using flow cytometry are still under development. Aggregation or adsorption of antibodies causes sub-nano sized particles or non-specific binding and largely affects the results of flow cytometric analysis of single sEVs. Comparison of control IgG and target-specific IgG is inappropriate because they have different characters. Here, we evaluate four preparation methods for flow cytometry, including ultracentrifugation, density gradient centrifugation, size exclusion chromatography (SEC), and the TIM4-affinity method by using tetraspanin-deficient sEVs. The ultracentrifugation or density gradient centrifugation preparation method has large false-positive rates for tetraspanin staining. Conversely, preparation methods using SEC or the TIM4-affinity method show specific detection of single sEVs, which elucidate the roles of sEV biogenesis regulators in the generation of sEV subpopulations. The methods are also useful for the detection of rare disease-related markers, such as PD-L1. Flow cytometric analysis using SEC or the TIM4-affinity method could accelerate research into sEV biogenesis and the development of sEV-based diagnostics and therapies.