Influence of repeated anaesthesia on physiological parameters in male Wistar rats: a telemetric study about isoflurane, ketamine-xylazine and a combination of medetomidine, midazolam and fentanyl

重复麻醉对雄性 Wistar 大鼠生理参数的影响:异氟烷、氯胺酮-赛拉嗪以及美托咪啶、咪达唑仑和芬太尼联合用药的遥测研究

阅读:9
作者:Maike Albrecht, Julia Henke, Sabine Tacke, Michael Markert, Brian Guth

Background

This study evaluated the influence of repeated anaesthesia using isoflurane (ISO, 2-3 Vol%), ketamine-xylazine (KX, 100 mg·kg(-1) + 5 mg·kg(-1), i.m.) or a combination of medetomidine-midazolam-fentanyl (MMF, 0.15 mg·kg(-1) + 2.0 mg·kg(-1) + 0.005 mg·kg(-1), i.m.) on heart rate (HR), arterial blood pressure (BP), body temperature (BT), duration of anaesthetic intervals and body weight (BW) in Wistar rats. Rats were instrumented with a telemetric system for the measurement of systolic, diastolic and mean arterial pressure (SAP, DAP, MAP), pulse pressure (PP), HR and BT during induction, maintenance and recovery of anaesthesia. Each anaesthesia was performed six times within three weeks. KX was not antagonized, but ISO delivery was terminated 40 minutes after induction and MMF was reversed with atipamezole-flumazenil-naloxone (AFN, 0.75 mg·kg(-1) + 0.2 mg·kg(-1) + 0.12 mg·kg(-1), s.c.).

Conclusion

HR, BP values, BT, duration of anaesthetic intervals and BW were affected differently by repeated anaesthesia performed with ISO, KX or MMF. ISO produced a reproducible anaesthesia, thereby being suitable for repeated use, but with a decrease of HR and BP throughout the six anaesthesias. The use of ISO in cases where these parameters should be unaffected is therefore not advised. The inability to produce a surgical tolerance, the reduction of sleeping time and BW, as well as the tissue necrosis are significant contraindications for a repeated use of KX. Only mild changes of BP were found with repeated MMF anaesthesia, so it seems suitable for serial use, unless the high BP and the low HR during the surgical plane of anaesthesia are undesirable for a special procedure.

Results

With repeated anaesthesia, ISO showed a decrease of HR and BP. A significant decrease of PP could be observed with repeated anaesthesia using MMF. HR and BP were not affected by repeated KX anaesthesia, but we noted a reduction of sleeping time and BW. Neither MMF nor ISO showed significant differences in the duration of anaesthetic intervals and BW. With KX we observed tissue necrosis at the injection site and surgical tolerance was not achieved in 25% of the anaesthesias performed.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。