Development and evaluation of serotype-specific recombinase polymerase amplification combined with lateral flow dipstick assays for the diagnosis of foot-and-mouth disease virus serotype A, O and Asia1

血清型特异性重组酶聚合酶扩增与侧流试纸检测相结合用于诊断口蹄疫病毒血清型 A、O 和 Asia1 的开发和评估

阅读:10
作者:Hongmei Wang, Peili Hou, Guimin Zhao, Li Yu, Yu-Wei Gao, Hongbin He

Background

Foot-and-mouth disease (FMD) caused by foot-and-mouth disease virus (FMDV) is one of the most highly infectious diseases in livestock, and leads to huge economic losses. Early diagnosis and rapid differentiation of FMDV serotype is therefore integral to the prevention and control of FMD. In this study, a series of serotype-specific reverse transcription recombinase polymerase amplification assays combined with lateral flow dipstick (RPA-LFD) were establish to differentiate FMDV serotypes A, O or Asia 1, respectively.

Conclusion

The development of serotype-specific RPA-LFD assay provides a rapid, sensitive, and specific method for differentiation of FMDV serotype A, O or Asia1, respectively. It is possible that the serotype-specific RPA-LFD assay may be used as a integral protocol for field detection of FMDV.

Results

The serotype-specific primers and probes of RPA-LFD were designed to target conserved regions of the FMDV VP1 gene sequence, and three primer and probe sets of serotype-specific RPA-LFD were selected for amplification of FMDV serotypes A, O or Asia 1, respectively. Following incubation at 38 °C for 20 min, the RPA amplification products could be visualized by LFD. Analytical sensitivity of the RPA assay was then determined with ten-fold serial dilutions of RNA of VP1 gene and the recombinant vector respectively containing VP1 gene from FMDV serotypes A, O or Asia1, the detection limits of these assays were 3 copies of plasmid DNA or 50 copies of viral RNA per reaction. Moreover, the specificity of the assay was assessed, and there was no cross reactions with other viruses leading to bovine vesicular lesions. Furthermore, 126 clinical samples were respectively detected with RPA-LFD and real-time PCR (rPCR), there was 98.41% concordance between the two assays, and two samples were positive by RPA-LFD but negative in rPCR, these were confirmed as FMDV-positive through viral isolation in BHK-21 cells. It showed that RPA-LFD assay was more sensitive than the rPCR method in this study.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。