The Impact of Ar or N2 Atmosphere on the Structure of Bi-Fe-Carbon Xerogel Based Composites as Electrode Material for Detection of Pb2+ and H2O2

Ar 或 N2 气氛对 Bi-Fe-C 干凝胶基复合材料作为检测 Pb2+ 和 H2O2 电极材料结构的影响

阅读:11
作者:Carmen I Fort, Mihai M Rusu, Liviu C Cotet, Adriana Vulpoi, Milica Todea, Monica Baia, Lucian Baia

Abstract

In this study, bismuth- and iron-embedded carbon xerogels (XG) were obtained using a modified resorcinol formaldehyde sol-gel synthesis method followed by additional enrichment with iron content. Pyrolysis treatment was performed at elevated temperatures under Ar or N2 atmosphere to obtain nanocomposites with different reduction yields (XGAr or XGN). The interest was focused on investigating the extent to which changes in the pyrolysis atmosphere of these nanocomposites impact the structure, morphology, and electrical properties of the material and consequently affect the electroanalytical performance. The structural and morphological particularities derived from X-ray diffraction (XRD), Raman spectroscopy, scanning electron microscopy (SEM), transmission electron microscopy (TEM), and X-ray photoelectron spectroscopy (XPS) measurements revealed the formation of the nanocomposite phases, mostly metal/oxide components. The achieved performances for the two modified electrodes based on XG treated under Ar or N2 atmosphere clearly differ, as evidenced by the electroanalytical parameters determined from the detection of heavy metal cations (Pb2+) or the use of the square wave voltammetry (SWV) technique, biomarkers (H2O2), or amperometry. By correlating the differences obtained from electroanalytical measurements with those derived from morphological, structural, and surface data, a few utmost important aspects were identified. Pyrolysis under Ar atmosphere favors a significant increase in the α-Fe2O3 amount and H2O2 detection performance (sensitivity of 0.9 A/M and limit of detection of 0.17 μM) in comparison with pyrolysis under N2 (sensitivity of 0.5 A/M and limit of detection of 0.36 μM), while pyrolysis under N2 atmosphere leads to an increase in the metallic Bi amount and Pb2+ detection performance (sensitivity of 8.44 × 103 A/M and limit of detection of 33.05 pM) in comparison with pyrolysis under Ar (sensitivity of 6.47·103 A/M and limit of detection of 46.37 pM).

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。