Discovery and Clinical Evaluation of MK-8150, A Novel Nitric Oxide Donor With a Unique Mechanism of Nitric Oxide Release

具有独特一氧化氮释放机制的新型一氧化氮供体 MK-8150 的发现和临床评估

阅读:6
作者:Clayton D Knox, Pieter-Jan de Kam, Karim Azer, Peggy Wong, Antwan G Ederveen, Diane Shevell, Christopher Morabito, Alan G Meehan, Wen Liu, Tom Reynders, Jean Francois Denef, Anna Mitselos, Daniel Jonathan, David E Gutstein, Kaushik Mitra, Shu Yu Sun, Michael Man-Chu Lo, Doris Cully, Amjad Ali

Background

Nitric oxide donors are widely used to treat cardiovascular disease, but their major limitation is the development of tolerance, a multifactorial process to which the in vivo release of nitric oxide is thought to contribute. Here we describe the preclinical and clinical

Conclusions

The novel nitric oxide donor MK-8150 induced significant blood-pressure lowering in dogs and humans for up to 14 days. However, despite a unique mechanism of nitric oxide release mediated by CYP3A4 metabolism, tolerance developed over 28 days, suggesting that tolerance to nitric oxide donors is multifactorial and cannot be overcome solely through altered in vivo release of nitric oxide. Clinical

Results

Single- and multiple-dose studies in telemetered dogs showed that MK-8150 induced robust blood-pressure lowering that was sustained over 14 days. The molecule was safe and well tolerated in humans, and single doses reduced systolic blood pressure by 5 to 20 mm Hg in hypertensive patients. Multiple-dose studies in hypertensive patients showed that the blood-pressure-lowering effect diminished after 10 days, and 28-day studies showed that the hemodynamic effects were completely lost by day 28, even when the dose of MK-8150 was increased during the dosing period. Conclusions: The novel nitric oxide donor MK-8150 induced significant blood-pressure lowering in dogs and humans for up to 14 days. However, despite a unique mechanism of nitric oxide release mediated by CYP3A4 metabolism, tolerance developed over 28 days, suggesting that tolerance to nitric oxide donors is multifactorial and cannot be overcome solely through altered in vivo release of nitric oxide. Clinical

Trial registration

URL: http://www.clinicaltrials.gov. Unique identifiers: NCT01590810 and NCT01656408.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。