Development of a LAMP-Based Diagnostic for the Detection of Multiple HIV-1 Strains

开发基于 LAMP 的多种 HIV-1 毒株检测诊断方法

阅读:6
作者:Amy Makler-Disatham, Massimo Caputi, Waseem Asghar

Abstract

Since its first appearance in 1981, HIV-1 has remained a global concern. Current methods for diagnosing HIV-1, while effective, are mostly specific to a given subtype of HIV-1 and often require expensive equipment and highly trained individuals to collect and process the sample. It is necessary to develop a sensitive diagnostic method that can be administered with minimal equipment to provide better care in low-resource settings. Loop-mediated isothermal amplification is a rapid and sensitive method for detecting the presence of specific nucleic acid sequences. Herein we report the development and comparison of two different HIV LAMP assays, integrase and VPR, as well as the comparison between TRIZol and magnetic beads RNA extraction methods for each assay. Our analysis shows that the integrase assay was able to detect the virus from multiple subtypes in under 30 min with a variable limit of detection (LOD) that was dependent on the HIV-1 subtype.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。