Conclusion
The SNP method can be a more time-efficient alternative to detect omicron variants of SARS-CoV-2 and distinguish their sublineages (BA.1, BA.2, and BA.4/5) by two different specific gene mutations in combination analysis (ΔH69/V70 and Q493R mutations).
Methods
This is a diagnostic analysis of 140 confirmed COVID-19 nasopharyngeal samples taken from the Kemayoran COVID Emergency Hospital Laboratory and the West Java Provincial Health Laboratory from April to October 2022. Data analysis was carried out to determine conformity and validity values.
Results
Analysis using Cohen's kappa coefficient test showed high conformity between SNP and WGS (p value <0.001; kappa coefficient = 0.948). SNP showed great validity values on omicron BA.1 (90% sensitivity; 100% specificity), omicron BA.2 (100% sensitivity; 99% specificity), and omicron BA.4/5 (99.2% sensitivity; 100% specificity).