Photoacoustic Imaging of Myocardial Infarction Region Using Non-Invasive Fibrin-Targeted Nanoparticles in a Rat Myocardial Ischemia-Reperfusion Model

在大鼠心肌缺血再灌注模型中使用非侵入性纤维蛋白靶向纳米粒子对心肌梗死区域进行光声成像

阅读:8
作者:Yanan Zhang, Xiajing Chen, Lingjuan Liu, Jie Tian, Lan Hao, Hai-Tao Ran

Background and purpose

Myocardial infarction (MI) is a serious threat to public health. The early identification of MI is important to promote appropriate treatment strategies for patients. Recently, strategies targeting extracellular matrix (ECM) components have gained attention. Fibrin is an ECM protein involved after MI. In this work, we constructed fibrin-targeted nanoparticles (NPs) by co-assembling a fibrin-targeted peptide (CREKA) and indocyanine green (ICG) and used them to enhance photoacoustic (PA) imaging for noninvasive detection of the infarct region to help diagnose MI.

Conclusion

This work provides new insights for non-invasive, real-time imaging techniques to detect the region of myocardial injury and help diagnose MI based on a PA imaging system with high sensitivity in optical imaging and deep penetration in ultrasound imaging.

Methods

ICG NPs modified with CREKA were prepared (CREKA-ICG-LIP NPs). Then, the fundamental characteristics, stability, safety, and targeting ability of the NPs were detected. Finally, in an ischemia-reperfusion (IR) injury model, the performance of the NPs in detecting the infarct region in the model on PA imaging was evaluated.

Purpose

Myocardial infarction (MI) is a serious threat to public health. The early identification of MI is important to promote appropriate treatment strategies for patients. Recently, strategies targeting extracellular matrix (ECM) components have gained attention. Fibrin is an ECM protein involved after MI. In this work, we constructed fibrin-targeted nanoparticles (NPs) by co-assembling a fibrin-targeted peptide (CREKA) and indocyanine green (ICG) and used them to enhance photoacoustic (PA) imaging for noninvasive detection of the infarct region to help diagnose MI.

Results

CREKA-ICG-LIP NPs were successfully constructed and showed excellent basic characteristics, a high safety level, and an excellent targeting ability. After intravenous injection, the CREKA-ICG-LIP NPs accumulated in the injured region in the IR model. Then, the PA signal in the infarct region could be detected by the ultrasound transducer of the Vevo LAZR Photoacoustic Imaging System.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。