Comparison of Telemedicine Screening of Diabetic Retinopathy by Mydriatic Smartphone-Based vs Nonmydriatic Tabletop Camera-Based Fundus Imaging

基于散瞳智能手机和免散瞳台式相机的眼底成像对糖尿病视网膜病变进行远程医疗筛查的比较

阅读:6
作者:Yong Seok Han, Mythili Pathipati, Carolyn Pan, Loh-Shan Leung, Mark Scott Blumenkranz, David Myung, Brian Chiwing Toy

Conclusions

Mydriatic smartphone-based imaging resulted in fewer ungradable photos compared to nonmydriatic table-top camera imaging and detected more patients with referral-warranted DR. Our study supports the use of mydriatic smartphone teleophthalmology as an alternative method to screen for DR.

Methods

This was a single-institutional, cross-sectional, comparative-instrument study. Fifty-six patients at a safety-net hospital underwent teleophthalmology screening for DR using standard, nonmydriatic fundus photography with a tabletop camera (Nidek NM-1000) and dilated fundus photography using a smartphone camera with lens adapter (Paxos Scope, Verana Health). Masked graders performed standardized photo grading. Quantitative comparisons were performed employing descriptive, κ, Bland-Altman, and receiver operating characteristic analyses.

Purpose

To compare dilated smartphone-based imaging with a nonmydriatic, tabletop fundus camera as a teleophthalmology screening tool for diabetic retinopathy (DR).

Results

Posterior segment photography was of sufficient quality to grade in 89% of mydriatic smartphone-imaged eyes and in 86% of nonmydriatic tabletop camera-imaged eyes (P = .03). Using the tabletop camera as the reference to detect moderate nonproliferative DR or worse (referral-warranted DR), mydriatic smartphone-acquired photographs were found to be 82% sensitive and 96% specific. Dilated smartphone imaging detected referral-warranted DR in 3 eyes whose tabletop camera imaging did not demonstrate referral-warranted DR. Secondary masked review of medical records for the discordances in referral-warranted status from the two imaging modalities was performed, and it revealed revised sensitivity and specificity values of 95% and 98%, respectively. Overall, there was good agreement between tabletop camera and smartphone-acquired photo grades (κ = 0.91 ± 0.1, P < .001; area under the receiver operating characteristic curve = 0.99, 95% CI, 0.98-1.00). Conclusions: Mydriatic smartphone-based imaging resulted in fewer ungradable photos compared to nonmydriatic table-top camera imaging and detected more patients with referral-warranted DR. Our study supports the use of mydriatic smartphone teleophthalmology as an alternative method to screen for DR.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。