Non-Targeted LC-MS/MS Assay for Screening Over 100 Lipid Mediators from ARA, EPA, and DHA in Biological Samples Based on Mass Spectral Fragmentations

基于质谱碎片的非靶向 LC-MS/MS 检测法,用于筛选生物样品中的 100 多种脂质介质(包括 ARA、EPA 和 DHA)

阅读:13
作者:Gabriel Dasilva, Silvia Muñoz, Salomé Lois, Isabel Medina

Abstract

A non-targeted strategy to simultaneously screen for over 100 lipid mediators from ω-6 ARA and ω-3 EPA and DHA fatty acids is presented. The method based on an extensive study of fragmentation patterns obtained by SPE-LC-MS/MS analysis-provided fingerprints to comprehensively elucidate and identify lipid mediators in biological samples. Many of these metabolites are associated to metabolic disorders, inflammatory, immune and oxidative stress. The methodology consisted of a three-step procedure. (1) SPE extraction of compounds from plasma and adipose tissue was followed by LC-MS/MS analysis operating in full scan mode. The methodology was validated for a group of 65 metabolites using standards. SPE recoveries ranged from 29-134% and matrix effect from 10-580%. LOD and LOQ ranged from 0.01 to 1765 ng/mL and 0.03 to 5884 ng/mL respectively, similarly than current analytical strategies based on MRM mode. (2) An extensive study of the mass spectra of a wide range of compounds was done to stablish a specific fragmentation pattern. Interestingly, illustrative fragmentations and new specific transitions to identify EPA and DHA lipid mediators have been innovatively established. (3) After analysis, 30 lipid mediators were tentatively identified in plasma and 35 in adipose tissue of rats according to the pre stablished fragmentation patterns. The hypothetical identification of compounds was validated by using reference standards. Around 85-90% of proposed identifications were correctly assigned and only 4 and 3 identifications failed in adipose tissue and plasma, respectively. The method allowed the identification of these metabolites without losing information by the use of predefined ions list. Therefore, the use of full scan mode together with the study of fragmentation patterns provided a novel and stronger analytical tool to study the complete profile of lipid mediators in biological samples than the analysis through MRM based methods. Importantly, no analytical standards were required at this qualitative screening stage and the performance and sensitivity of the assay were very similar to that of a MRM method.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。