Confirmation of sentinel lymph node identity by analysis of fine-needle biopsy samples using inductively coupled plasma-mass spectrometry

使用电感耦合等离子体质谱法分析细针活检样本来确认前哨淋巴结身份

阅读:15
作者:Alison Beavis, Michael Dawson, Philip Doble, Richard A Scolyer, Roger Bourne, Ling-Xi L Li, Rajmohan Murali, Jonathan R Stretch, Cynthia L Lean, Roger F Uren, John F Thompson

Background

The sentinel lymph node (SLN) biopsy technique is a reliable means of determining the tumor-harboring status of regional lymph nodes in melanoma patients. When technetium 99 m-labeled antimony trisulfide colloid (99 mTc-Sb2S3) particles are used to perform preoperative lymphoscintigraphy for SLN identification, they are retained in the SLN but are absent or present in only tiny amounts in non-SLNs. The present study investigated the potential for a novel means of assessing the accuracy of surgical identification of SLNs. This involved the use of inductively coupled plasma-mass spectrometry (ICP-MS) to analyze antimony concentrations in fine-needle biopsy (FNB) samples from surgically procured lymph nodes.

Conclusions

Our results show that ICP-MS analysis of antimony concentrations in FNB specimens from lymph nodes can accurately confirm the identity of SLNs. Used in conjunction with techniques such as proton magnetic resonance spectroscopy for the nonsurgical evaluation of SLNs, ICP-MS analysis of antimony concentrations in FNB samples could potentially serve as a minimally invasive alternative to surgery and histopathologic evaluation to objectively classify a given node as sentinel or nonsentinel and determine its tumor-harboring status.

Methods

A total of 47 FNB samples from surgically excised lymph nodes (32 SLNs and 15 non-SLNs) were collected. The SLNs were localized by preoperative lymphoscintigraphy that used 99 mTc-Sb2S3, blue dye, and gamma probe techniques. The concentrations of antimony were measured in the FNB samples by ICP-MS.

Results

The mean and median antimony concentrations (in parts per billion) were .898 and .451 in the SLNs, and .015 and .068 in the non-SLNs, the differences being highly statistically significant (P < .00005). Conclusions: Our results show that ICP-MS analysis of antimony concentrations in FNB specimens from lymph nodes can accurately confirm the identity of SLNs. Used in conjunction with techniques such as proton magnetic resonance spectroscopy for the nonsurgical evaluation of SLNs, ICP-MS analysis of antimony concentrations in FNB samples could potentially serve as a minimally invasive alternative to surgery and histopathologic evaluation to objectively classify a given node as sentinel or nonsentinel and determine its tumor-harboring status.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。